Multiple Column Support: Puriflash® Open Access Lab CarouXel

Multiple Column Support: Puriflash® Open Access Lab CarouXel

puriFlash® Open
Access Lab
CarouXel

Increase your productivity tenfold
by using the Multi-Column Support

puriFlash® Open
Access Lab
CarouXel

Increase your productivity tenfold
by using the Multi-Column Support

Sequential purification of up to 10 samples thanks to our multi-column support: CarouXel.
Easy to use, it will boost lab productivity in no time at all.

Ready? Position your columns (up to format F0330) using the turntable

And go: Create your methods without having to wait for the previous purification to finish

Start and leave!
The purifications automatically line up, one after the other

Ready? Position your columns (up to format F0330) using the turntable

And go: Create your methods without having to wait for the previous purification to finish

Start and leave!
The purifications automatically line up, one after the other

No two purifications in the lab are the same.
To help maximize the optimisation of your day and in order to let the columns turn without your presence being required, the CarouXel has been designed to offer you maximum compatibility with the various injection modes available.
Completely adapted to the purification and its requirements, this module will allow you to establish a centralized purification device for an entire laboratory with minimal space requirements.

Solo or shared

Go into multi-user mode (if you like).

Thanks to our InterSoft X software, and more particularly its sample queue function, multiple users will be able to benefit from this column support and use it by configuring the methods of their choice, even during one run. They line up one after the other.

The centralisation of one or more purification systems (depending on the number of CarouXel in your laboratory) will improve the yield of these systems by increasing their utilisation and thus limiting downtimes.

Automation at the service of all those who have no time to lose.
If you are among them, then we will proceed:

Fully piloted and controlled by our InterSoft X software, CarouXel will automatically position itself on the selected column path to start the method. Thus, you no longer have any risk of error.
And, thanks to the sequence of methods created in advance, you will not waste time between purifications. If you like, you can watch how the CarouXel works for you, however it does not require monitoring.

Automation at the service of all those who have no time to lose.
If you are among them, then we will proceed:

Fully piloted and controlled by our InterSoft X software, CarouXel will automatically position itself on the selected column path to start the method. Thus, you no longer have any risk of error.
And, thanks to the sequence of methods created in advance, you will not waste time between purifications. If you like, you can watch how the CarouXel works for you, however it does not require monitoring.

Liquid injection or solid deposition?
Everything is possible.

CarouXel offers you numerous
injection modes for your samples:

– Liquid on dry column
– Liquid on balanced column
– Liquid, pre-absorbed on silicone or celite
– Liquid via an automatic injection valve
– Liquid via an external pump
– Solid particle deposition in a dry-load

Liquid injection or solid deposition?
Everything is possible.

CarouXel offers you numerous
injection modes for your samples:

– Liquid on dry column
– Liquid on balanced column
– Liquid, pre-absorbed on silicone or celite
– Liquid via an automatic injection valve
– Liquid via an external pump
– Solid particle deposition in a dry-load

Safety for the samples.
Automatic emptying and cleaning.

Give your columns a bit of a clean-up before they take a ride in the CarouXel.

Safety first: Automatic emptying is carried out between each method so as not to contaminate the subsequent purifications. The purpose of this emptying is to prevent the solvents used during the previous purifications from entering the new column.

The safety factor is also enhanced by a retention tank with a leak detector.

Safety for the samples.
Automatic emptying and cleaning.

Give your columns a bit of a clean-up before they take a ride in the CarouXel.

Safety first: Automatic emptying is carried out between each method so as not to contaminate the subsequent purifications. The purpose of this emptying is to prevent the solvents used during the previous purifications from entering the new column.

The safety factor is also enhanced by a retention tank with a leak detector.

Boost safety or collect more?
No worries – both options are compatible, so no problem.

For even better safety:
The 10-way-valve multi waste container option

Opt for increased safety of your samples by choosing the “10-way-valve multi waste container”. This allows you to allocate each column path to a waste bin, thus avoiding possible cross- contamination between different purifications.

To collect more and more:
The second fraction collector option

Increase your collection capacity with the “second collector” option. This option allows you to add up to 4 additional racks.

Capacity from 10 columns up to format F0330

Sequential and automated chaining

Controlled by the InterSoft X software

Multi-user sample queue

Time savings

Automatic purification of the flow paths between two injections

Multiple injection procedures for solid and liquid samples

Need more information?

Ready to configure yours?